Electrical8

Magnetic contactor

LC1D65…C  110V

TeSys

 

Nos.02
Magnetic contactor

LC1E 25 01, 380V

Easy Pact TVS

 

Nos.02
Thermal Relay

LRD 07, 1.6-2.5 A

 

Nos.02
  1. 9.
Thermal Relay

LRD 14,  7-10 A

 

Nos.04
Thermal Relay

LRD 10, 4-6 A

 

Nos.02
Thermal Relay

LRD 22, 16-24 A

 

Nos.04
Thermal Relay

LR9  D5369, 90-150 A

 

Nos.06
Thermal Relay

LRE 22, 16-24 A

 

Nos.06
Thermal Relay

LR D33, 37-50 A

 

Nos.02
Thermal Relay

 

Nos.06
Auxiliary Contactor

LAD8 N11

 

Nos.06
Auxiliary Contactor

LADN20

 

Nos.02
Fuse

4 A gG,690~50KA, 10×38

RT18-32

 

Nos.24
  1. 9.
Fuse

2 A gG, 690~50KA, 10×38

RT28-32

 

Nos.24
  1. 10.
Indicating Light:

Model No: AD11-16/41-6GZ

AC 380V

 

Nos.20
PLUG & RECEPTACLE
EBR RECEPTACLE INTERLOCKED WITH BREAKER FOR HAZARDOUS LOCATIONS

CAT NO. EBR1534FD150, 600V, 50/60 Hz, 3 W, 4P, Receptacle Max. Amp Rating- 150A, Circuit Breaker CAT NO. FD3150KLS

Max Amp Rating: 150A

 

Nos.04
RECEPTACLE INTERLOCKED WITH SWITCH

FOR HAZARDOUS LOCATIONS

CAT NO. EFSR-20232, Model B

20 Amp, 2 HP, 250 VAC

 

Nos.10
POWERTITE Receptacle

CAT NO.ADR3023

30A, 2W, 4P, STY-2

250VDC, 600VAC

 

Nos.04
POWERTITE Receptacle

CAT NO.ADR3034

30A, 3W, 4P, STY-2

250VDC, 600VAC

 

Nos.04
POWERTITE Receptacle

CAT NO.ADR6044

60A, 4W, 4P, STY-1

250VDC, 600VAC

 

Nos.01
POWERTITE Receptacle

CAT NO.ADR1034

100A, 3W, 4P, STY-2

250VDC, 600VAC

 

Nos.02
POWERTITE Receptacle

CAT NO.ADR1044

100A, 4W, 4P, STY-1

250VDC, 600VAC

 

Nos.01
POWERTITE Receptacle

CAT NO.ADR20034

200A, 3W, 4P, STY-2

250VDC, 600VAC

 

Nos.04
POWERTITE Receptacle

CAT NO.ADR20044

200A, 4W, 4P, STY-1

250VDC, 600VAC

 

Nos.02
4-Pin Socket

Part No.A12-PM-416-F-01

Make: CCS (CNNECTOR & CABLE SPECIALTIES,LTE),

Nos.02
4-Pin Plug

Part No.A12-SP-416-M-08B-01

Make: CCS (CNNECTOR & CABLE SPECIALTIES,LTE),

Nos.02
7-Pin Plug

Part No.A12-SP-712-M-10B

Make: CCS (CNNECTOR & CABLE SPECIALTIES,LTE),

Nos.02
10-Pin Plug

Part No.A12-SP-1016M-14B

Make: CCS (CNNECTOR & CABLE SPECIALTIES,LTE),

Nos.02
20-Pin Plug

Part No.A12-SP-2012-M-18B

Make: CCS (CNNECTOR & CABLE SPECIALTIES,LTE),

Nos.02
Plug for Hazardous Locations Watertight

CAT NO. ECP-20232, Model D

20 Amp, 2 HP, 250 VAC

 

Nos.10
POWERTITE PLUG

CAT NO.AP6044BC

60A, 4W, 4P, STY-1

 

Nos.04
POWERTITE PLUG

CAT NO.AP20044CD

200A, 4W, 4P, STY-1

 

Nos.02
POWERTITE PLUG

CAT NO.AP20034CD

200A, 3W, 4P, STY-2

 

Nos.04
POWERTITE Receptacle

CAT NO.ADR6044

60A, 4W, 4P, STY-1

250VDC, 600VAC

 

Nos.01
POWERTITE Receptacle

CAT NO.ADR1034

100A, 3W, 4P, STY-2

250VDC, 600VAC

 

Nos.02

RTD Sensor, Solid End Bearing Temperature, P/N:G0008089
RTD Sensor, Liquid End Bearing Temperature, P/N:G0008090
Speed Sensor, P/N:G0007861
Fuse, Dual Pole, Class J, 50A, P/N:G0008073
Fuse, Fast Acting, 50A, P/N:G0008072
Fuse-1.5A, P/N:G0007981
Fuse-Kit, Dual Rej, Pori Sigl, Midget Sec, P/N:G0008069
Fuse-3A, P/N:G0007589
Fuse-3A, FNQ-R-5
Fuse, Cube Style, 40A, 600V, P/N:G0007583
Fuse, Cube Style, 100A, 600V, P/N:G0003484
Fuse, Time Delay, 2.5A, 600Vac, Style CC, P/N:G0002910
Fuse, Time Delay, 7A, 250Vac, Style CC, P/N:G0002911
Air Filter, P/N:G0003565
Intrinsic Safe Barrier, Vibration Switch, P/N:G0007232
Intrinsic Safe Barrier, RTD Sensor, P/N:G0007233
Intrinsic Safe Barrier, Speed Sensor, P/N:G0007234
Surge Suppressor, 120V, P/N:G0003504
Power supply, 24Vdc, 5A, P/N:G0003552

i.CW Auto Transformer Ballast

400W   S51

P/N. 71A84N3, 120/220-240V, 4.00/2.00A, 50 Hz

 

ii.Lamp:

VENTURE

MS 400W/H75/PS/740

iii.Lamp Holder:

62RF

MOGUL BASE  LH200

STARTING PULSE RATING 5KV, 600VAC, 1500W

iv.Capacitor:

64 MFD±3% 280 VAC 50/60 Hz

P/N: 7C640S28RA

 

v.Lamp Ignitor

P/N: LI501H4

 

02.Fluorescent Light Used in Hazardous Locations, Class I, Groups A, B, C &D, Division-2

CATALOG No. MAR22654 UEML

Lamp Watts-32, 50/60 Hz, 2´40W

Voltage/Current-: 120/0.47

277/0.20

 

03.Fluorescent Light Used in Hazardous Locations, Class I, Groups A, B, C &D, Division-2

CATALOG No. MAR22654U L

Lamp Watts-32, 50/60 Hz, 2´40W

Voltage/Current-: 120/0.47

277/0.20

 

i.Lamp

SYLVANIA

OCTRON®/ECO®

4-100K, 32W Made in USA

ii.Electronic Ballast

INTELLIVOLT

120V to 277V 50/60Hz

P/N: 4435 290 35871 REV.A

Optanium

IOP-2P32-N Instant Start Electronic Ballast

 

iiLamp Holder

660W, 600V

LEVITON, Mexico

1.Hand crimp Tool Complete with carrying case, Checking gage and complete insulation for crimping#10 through #18 contracts of MOD-II

P/N: TP-201351-AG

 

2.Contact Insertion & Removal Tool( For MOD II), Make: Pyle National

a)       Insertion Size: 10/12/16/18

b)       Removal Tools Size: 10/12/16/18

3.DXSL Super Dehumidifier

Model: MOH-720B

 

4.Heavy duty Battery Charger

Input: 200-240 VAC

Output: 12-24 VDC @ 15 Amps. Or above complete with volt meter& ammeter

 

5.Cater piller Engine 3512B Gen SR4B Battery Charger, Output- 24 VDC, Input: 380 VAC, 50 Hz, No: C201310231417966, 4NIC-CD240, B280´180´120.
6.UPS

2KVA, Input: 220 VAC, Output: 220 VAC, 50 Hz, Make: CASTLE C2k.

7.Pressure Switch, MERCUID DIVISION, Dwyer Instruments Inc., USA,

Cat. No. SA111  1E-S5-K2, Serial: A1BU, Max Pressure: 120 PSI, Limit Switch For Use in Hazardous Location, Class 1, Group B, C & D, Class 2, Group E, F & G, Max 15 Amp, 125, 250, 480 VAC, ENCL: Type 4

8.Temp. & Humidity Monitor

Model: JWSK-52SC1C

Power: DC 24V,

Temp.: -10°C~50°C, Accuracy: ±0.5°C

Hum.: 0%FH~100%RH,

Accuracy: ±3%RH (25°C, 5%RH~95%RH)

Ambient Temp.: -20°C ~60°C

 

9.Industrial Control Equip. For Haz. Locs.

Switch Heavy Duty, 600VAC Max.Factory Sealed

CAT NO. EDS2192 S153

 

10.Sensor

Model: 10109470-002

Serial No.1307571-01

F/S CALIB

 

11.Proximity Sensor, SNSR ASSY (UL), EVISION N 0009, Drilling Instrumentation for Use in Hazardous Location,

Part No. 232389, NOV, Martin Decker Totco.

12.Air Pressure Switch

Industrial Control Equipment for Hazardous Location, Cat No. 1950-20-2F, Diaphragm Vertical, Max Press. 45 In WC (11kPa), Surge Press. 10 PSI (68kPa), Temp. -40°F to 140°F Electrical Ratings: 15 Amp, 125, 250, 480 VAC, 1/8 HP 125 VAC, ¼ HP 250 VAC

Rain Tight, (ENCL. 3)

 

13.Solenoid Valve

Model: VL/O-3-1/4  9984  D502

1: 0.95-10 bar/14.4-145 PSI

11:0-10bar/145psi

12.110: 1-10bar/ 13.8-145psi

 

14.Solenoid Valve

Model: MFH-3-1/4  9964  D202

1.5-8 bar/21-120 PSI

 

15.Solenoid Valve

Model: MFH-3-1/4-EX  9-5898 D102

1.5-8 bar/21-120 PSI

 

16.Solenoid Valve

Model: OS-1/4-B  6682  CN 14

1-10 bar/14.5-145PSI

 

17.MAGNET-SCHULTZ

D-87700 Memmingen, GBRE022AMXE07V 24VDC 0.19A, 4.3W, 40°C

18.Fluke 233 Remote Display TRUE RMS Digital Multimeter
19.Fluke 376 True RMS AC/DC Clamp meter with iFlex
20.Fluke 1550C 5 kV Insulation Tester
21.Pressure Transmitter

Model: JYB-KB-KAG, 0-10Mpa, 4~20mA, 24 VDC

 

22.Pressure Transmitter

Model: JYB-KB-KAG, 0-40Mpa, 4~20mA, 24 VDC

 

23.Pressure Transmitter

HG300G09NMP2S2i,

Range: 0~35Mpa, 24 VDC, 4-20 mA

 

24.SBW Temperature Transmitter

Marking: ExdIIBT5,

NO: CN Ex10.1532, Range: -45°C~100°C, Accuracy: ±0.2%, Output: 4~20 mADC

 

25.Incremental Optical Encoder,

Model No: HS35F-F-14L-R2-SS-500-AB-3904-TB-5V-EX-S

Part No: 01064-077

VDC IN: 5

 

26.Incremental Optical Encoder,

Model No: HS35F-100-R2-SS-1024-ABZC-5V/V-SM18_EX,

Part No: 01075-111

VDC IN: 5

 

27.Handle

W. GESSMANN GmbH,

D-74211, Leingarten,

PW1012935-010

S13, 153631010-0021

Type: BVV81B3M-03ZP-X, Q556

 

28.Handle

W. GESSMANN GmbH,

D-74211, Leingarten,

F. No. 130 0529120-47

Type: V61B3-01ZP, 6A, 24VDC, Q567

 

29.BARRIER,  K-System,

KFD2-STC4-EX120,

P/N: 122581

 

30.Gal vanically Isolated Safety Barrier,

DEMKO 03 ATEX 0313867X,

BEI P/N: 60004-003

Output Logic: 12-24

Input Supply VS: 12-24

 

31.Intrinsic Safety Barrier

Model: NPEXA-C311P

Input & Output: 4-20 mA

 

32.Implication Board

Power Supply: 24VDC±10%

Max. Consumption: 50W

Model: E-ME-AC-01F

 

33.Liquid Level Sensor

HG500, 0~0.6m, ExiaIICt6, Accuracy: ±0.25%

4-20mA, 1307076

34.Blower Assembly used in Drilling Drives GE Motor 5GEB22 A5

Product: AIRDYNE,

Model: 22A5-15CW-30357, Spec No: 5436601

 

35.Liquid Level Sensor

SITRANS Probe LU

Model: 7ML52211BA1B

Amb. Temp. -40°C to 8o°C

Power Ratings: 24VDC to 30VDC Max. 4-20mA

Make: Siemens Milltronics Process Instruments, Peterburgh,

36.Explosion proof operating pole device:

Model: B2C53-K1WF2

R.Volt: 380 V

R.Current: 15A

 

37.Video Camera Moving Part, ExdII CT6,

YTY-A13DI, DC12V, 800 ma, IP-65, CNEx 07.0627, 0907-38

38.Internal Card No. 009010

of

Ex-Proof Adapter

Type: BZQ-1  Voltage-220

Ex-mark: ExdibIIBT5  No. 90722

 

39.Ex-proof Audible and Visual Alarm

Type: BBJ-2  Volt-220

Ex-mark: ExdibIIBT5  No. 90724

Internal Card No.

 

40.Ex-proof Address Telephone of No Master

Type: HWBK Voltage- 220V

Ex-mark: ExdibIIBT5  No. 90725

Internal Card No. 009005

 

41.Internal Card No. 009005

of

Indoor Telephone of No Master

Type: HWSK Voltage- 220V

Ex-mark: ExdibIIBT5  No. 90736

 

42.Ex proof Loud Speaker

Type: BYS Power: 25W

No. 90734

 

43.Blower Motor

CATALOG# YC15P1Z-C

FR 254T, TYPE-LCE,  ENCL- TE, PH3, HP-15, RPM-2915, 50 HZ, 380V,  21.7 A, MAX AMB-60°C, INSUL CLASS-F, DUTY-CONT.

 

44.Flameproof Three Phase Induction Motor,

Type: YB3-160L-4W, Standard No: Q/NFD10.2-2011,RATINGS-1, cosF-0.86, 15 KW, 380V, 29.2A, 1460 r/min, 50 Hz, IP-55, INS. CL-F, CONN. D, h-90.6% , WEIGHT-178 kg

 

45.Automatic Voltage Regulator (AVR) ENGGA AVR Model: WT-2 for  EG-315M-300N Generator
46.Engine control module, Deep See Electronics

Model: DSE3110

47.Engine control module, Deep See Electronics

Model: DSE7310

 

Posted in InventoryList.