Level Meters,Chongqing chuanyi
High-energy sound level meter
HS series : HS–AWI(0–60m) measurement
MW series: MW(0–10m) measurement
Sultan series: AWI(0–60m) measurement
MPS1000 series PULSE RADAR
MPS1200
Application:Measuring corrosive liquid in complex conditions
Measurement range:0-35m
Process of Connection:1-1/2’’NPT whorl or flange
Temperature:-40℃~150℃
Pressure:-1.0~3 kgf/cm2
Accuracy:±1cm
Frequency Range:6GHz
Signal Output:4~20 mA HART
Power supply:24VDC 、2-20mA、HART、Two-wires
24VDC 、4-20mA、Four-wires
220VAC 、4-20mA、Four-wires
4-20 mA output calibration for range set. By HART protocol to communicate
MPS1300
Application:Measuring liquid and solid in complex conditions
Measurement range:0-70m
Process of Connection:Flange
Temperature:-40℃~350℃
Pressure:-1.0~40kgf/cm2
Accuracy:±1cm
Frequency Range:6GHz
Signal Output:4~20 mA HART
Power supply:24VDC 、2-20mA、HART、Two-wires
24VDC 、4-20mA、Four-wires
220VAC 、4-20mA、Four-wires
4-20 mA output calibration for range set. By HART protocol to communicate
MPS1300
Application:Measuring liquid and solid in complex conditions
Measurement range:0-70m
Process of Connection:Flange
Temperature:-40℃~150℃
Pressure:-1.0~2kgf/cm2
Accuracy:±1cm
Frequency Range:6GHz
Signal Output:4~20 mA HART
Power supply:24VDC 、2-20mA、HART、Two-wires
24VDC 、4-20mA、Four-wires
220VAC 、4-20mA、Four-wires
4-20 mA output calibration for range set. By HART protocol to communicate
MPS3000 series PULSE RADAR
MPS3100
Application:Measuring corrosive liquid
Measurement range:0-20m
Process of Connection:1-1/2’’ NPT、G3 whorl or flange
Temperature:-40℃~150℃
Pressure:-1.0~3 kgf/cm2
Accuracy:±3mm
Frequency Range:26GHz
Signal Output:4~20 mA HART
Power supply:24VDC 、2-20mA、HART、Two-wires
24VDC 、4-20mA、Four-wires
220VAC 、4-20mA、Four-wires
MPS3200
Application:Slightly corrosive liquid
Measurement range:0-35m
Process of Connection: flange
Temperature:-60℃~400℃
Pressure:-1.0~40kgf/cm2
Accuracy:±3mm
Frequency Range:26GHz
Signal Output:4~20 mA HART
Power supply:24VDC 、2-20mA、HART、Two-wires
24VDC 、4-20mA、Four-wires
220VAC 、4-20mA、Four-wires
MPS3300
Application:Measuring corrosive liquid in complex conditions
Measurement range:0-20m
Process of Connection: flange
Temperature:-40℃~150℃
Pressure:-1.0~16kgf/cm2
Accuracy:±3mm
Frequency Range:26GHz
Signal Output:4~20 mA HART
Power supply:24VDC 、2-20mA、HART、Two-wires
24VDC 、4-20mA、Four-wires
220VAC 、4-20mA、Four-wires
MPS3600
Application:Lump, granular solid measurement
Measurement range:0-35m
Process of Connection: flange
Temperature:-60℃~400℃
Pressure:40kgf/cm2(Universal joint type instrument for atmospheric pressure)
Accuracy:±3mm
Frequency Range:26GHz
Signal Output:4~20 mA HART
Power supply:24VDC 、2-20mA、HART、Two-wires
24VDC 、4-20mA、Four-wires
220VAC 、4-20mA、Four-wires
MPS3700
Application:Granular, powdery solid measurement
Measurement range:0-70m
Process of Connection: flange
Temperature:-60℃~400℃
Pressure:40kgf/cm2(Universal joint type instrument for atmospheric pressure)
Accuracy:±3mm
Frequency Range:26GHz
Signal Output:4~20 mA HART
Power supply:24VDC 、2-20mA、HART、Two-wires
24VDC 、4-20mA、Four-wires
220VAC 、4-20mA、Four-wires
Guided Microwave Radar Transmitter
Category MGS2100、MGS4100
Application liquid
Measurement range 0-20m
Measuring Medium • the permittivity of liquid is equal or greater than 1.4
- viscousliquid
Cable type electrode φ6mm(cable type )
Process of connection 1½NPT or flange
Temperature -190℃~150℃(Apply to MGS2000 type)
-190℃~400℃(Apply to MGS4000 type)
Pressure -1.0~40kgf/cm2
power supply Normal power supply: 18~36VDC, ripple voltage: 100mv.vp.p
EXia power supply: 18~28VDC, ripple voltage::100mv.vp.p
Maximum current: 22.5mA
Category MGS2200、MGS4200
Application Liquid, powder and solid particles
Measurement range 0-4m
Measuring Medium • the permittivity of everything is equal or greater than 1.4 and CST≤500cst
For steam and foam has a strong inhibition, measurement is not affected
Cable type electrode φ10mm、φ12mm、φ16mm(stick)
Process of connection 1½NPT or flange
Temperature -190℃~150℃(Apply to MGS2000 type)
-190℃~400℃(Apply to MGS4000 type)
Pressure -1.0~40kgf/cm2
power supply Normal power supply: 18~36VDC, ripple voltage: 100mv.vp.p
EXia power supply: 18~28VDC, ripple voltage::100mv.vp.p
Maximum current: 22.5mA
Category MGS2500、MGS4500
Application Liquid
Measurement range 0-4m
Measuring Medium • the permittivity of everything is equal or greater than 1.4 and CST≤500cst
- measurement have nothing to do with the electrical conductivity of medium
Cable type electrode Coaxial rod electrode
Process of connection 1½NPT or flange
Temperature -190℃~150℃(Apply to MGS2000 type)
-190℃~400℃(Apply to MGS4000 type)
Pressure -1.0~40kgf/cm2
power supply Normal power supply: 18~36VDC, ripple voltage: 100mv.vp.p
EXia power supply: 18~28VDC, ripple voltage::100mv.vp.p
Maximum current: 22.5mA