Ex-proof Safety Barrier for Industry
Designed according to GB3836.1: 2000 & GB3836.4:2000 requirement, adopt unique patent
technology to realize the isolation between power, signal input and output, largely
improve the Antiinterference capability of the monitor and control circuit, very easy and
safe to use. Connect with all kinds of translators, electric/gas converter, electric/gas
valve localizer, approaching switch, electromagnetic valve, etc and compose intrinsically safe system.
ü Certification of explosion protection [Exia]IIC
ü Single/dual channels with very low cost
ü Signal transmission, conversion, allocation function optional
ü Suited to various I/O system
ü Imported PHOENIX covering
ü DIN35 standard installation
Series NO. | Input | Output | Channel | |
TR100PI-EX | Pt100,Cu50,Cu100 | 0/4-20mA, | 1 input & 1 output | |
TR200PI-EX | Pt100,Cu50,Cu100 | 0/4-20mA, | 2 input & 2 output | |
TR600PI-EX | Pt100,Cu50,Cu100 | 0/4-20mA, | 1 input & 2 output | |
TR102PI-EX | Pt100,Cu50,Cu100 | 0/4-20mA, | 1 input & 1 output | |
TR202PI-EX | Pt100,Cu50,Cu100 | 0/4-20mA, | 2 input & 2 output | |
TR602PI-EX | Pt100,Cu50,Cu100 | 0/4-20mA, | 1 input & 2 output |
Ex-proof Safety Barrier for Industry
Designed according to GB3836.1: 2000 & GB3836.4:2000 requirement, adopt unique patent
technology to realize the isolation between power, signal input and output, largely
improve the Antiinterference capability of the monitor and control circuit, very easy and
safe to use. Connect with all kinds of translators, electric/gas converter, electric/gas
valve localizer, approaching switch, electromagnetic valve, etc and compose intrinsically safe system.
ü Certification of explosion protection [Exia]IIC
ü Single/dual channels with very low cost
ü Signal transmission, conversion, allocation function optional
ü Suited to various I/O system
ü Imported PHOENIX covering
ü DIN35 standard installation
Series NO. | Input | Output | Channel |
TS100-EX | NAMUR Sensors Mechanical Jionts | Relay Output | 1 input & 1 output |
TS200-EX | NAMUR Sensors Mechanical Jionts | Relay Output | 2 input & 2 output |
TS101-EX | NAMUR Sensors Mechanical Jionts | Transistor Output | 1 input & 1 output |
TS201-EX | NAMUR Sensors Mechanical Jionts | Transistor Output | 2 input & 2 output |
TS102-EX | NAMUR Sensors | I :0/4-20mA | 1 input & 1 output |
TS202-EX | NAMUR Sensors | I :0/4-20mA | 2 input & 2 output |
Ex-proof Safety Barrier for Industry
Designed according to GB3836.1: 2000 & GB3836.4:2000 requirement, adopt unique patent
technology to realize the isolation between power, signal input and output, largely
improve the Antiinterference capability of the monitor and control circuit, very easy and
safe to use. Connect with all kinds of translators, electric/gas converter, electric/gas
valve localizer, approaching switch, electromagnetic valve, etc and compose intrinsically safe system.
ü Certification of explosion protection [Exia]IIC
ü Single/dual channels with very low cost
ü Signal transmission, conversion, allocation function optional
ü Suited to various I/O system
ü Imported PHOENIX covering
ü DIN35 standard installation
Series NO. | Input | Output | Channel | |
TC100PI-EX | R,S,K,J,T,B,E Thermometry,mV signal | 0/4-20mA, | 1 input & 1 output | |
TC600PI-EX | R,S,K,J,T,B,E Thermometry,mV signal | 0/4-20mA, | 1 input & 2 output | |
Series NO. | Input | Output | Channel | |
TC100PI-EX-SP | R,S,K,J,T,B,E Thermometry,mV signal | 0/4-20mA, | 1 input & 1 output | |
TC600PI-EX-SP | R,S,K,J,T,B,E Thermometry,mV signal | 0/4-20mA, | 1 input & 2 output |
Ex-proof Safety Barrier for Industry
Designed according to GB3836.1: 2000 & GB3836.4:2000 requirement, adopt unique patent
technology to realize the isolation between power, signal input and output, largely
improve the Antiinterference capability of the monitor and control circuit, very easy and
safe to use. Connect with all kinds of translators, electric/gas converter, electric/gas
valve localizer, approaching switch, electromagnetic valve, etc and compose intrinsically safe system.
Series NO. | Remark | Input | Output | Channel | |
TA100-EX | DC current input analog detection type safety barrier | 0/4-20mA | 0/4-20mA, | 1 input & 1 output | |
TA200-EX | DC current input analog detection type safety barrier | 0/4-20mA | 0/4-20mA, | 2 input & 2 output | |
TA600-EX | DC current input analog detection type safety barrier | 0/4-20mA | 0/4-20mA, | 1 input & 2 output | |
Series NO. | Remark | Input | Output | Channel | |
TAF100-EX | DC current input analog operation type safety barrier | 0/4-20mA | 0/4-20mA, | 1 input & 1 output | |
TAF200-EX | DC current input analog operation type safety barrier | 0/4-20mA | 0/4-20mA, | 2 input & 2 output | |
TAF600-EX | DC current input analog operation type safety barrier | 0/4-20mA | 0/4-20mA, | 1 input & 2 output |