Safety Barrier

Ex-proof Safety Barrier for Industry

Designed according to GB3836.1: 2000 & GB3836.4:2000 requirement, adopt unique patent
technology to realize the isolation between power, signal input and output, largely
improve the Antiinterference capability of the monitor and control circuit, very easy and
safe to use. Connect with all kinds of translators, electric/gas converter, electric/gas
valve localizer, approaching switch, electromagnetic valve, etc and compose intrinsically safe system.

ü  Certification of explosion protection  [Exia]IIC

ü Single/dual channels with very low cost

ü Signal transmission, conversion, allocation function optional

ü Suited to various I/O system

ü Imported PHOENIX covering

ü DIN35 standard installation

Series NO.

Input

Output

Channel

TR100PI-EX

Pt100,Cu50,Cu100

0/4-20mA,
0/1-5V,0/2-10V

1 input & 1 output

TR200PI-EX

Pt100,Cu50,Cu100

0/4-20mA,
0/1-5V,0/2-10V

2 input & 2 output

TR600PI-EX

Pt100,Cu50,Cu100

0/4-20mA,
0/1-5V,0/2-10V

1 input & 2 output

TR102PI-EX

Pt100,Cu50,Cu100

0/4-20mA,
0/1-5V,0/2-10V

1 input & 1 output

TR202PI-EX

Pt100,Cu50,Cu100

0/4-20mA,
0/1-5V,0/2-10V

2 input & 2 output

TR602PI-EX

Pt100,Cu50,Cu100

0/4-20mA,
0/1-5V,0/2-10V

1 input & 2 output

 Ex-proof Safety Barrier for Industry

Designed according to GB3836.1: 2000 & GB3836.4:2000 requirement, adopt unique patent
technology to realize the isolation between power, signal input and output, largely
improve the Antiinterference capability of the monitor and control circuit, very easy and
safe to use. Connect with all kinds of translators, electric/gas converter, electric/gas
valve localizer, approaching switch, electromagnetic valve, etc and compose intrinsically safe system.

ü  Certification of explosion protection  [Exia]IIC

ü Single/dual channels with very low cost

ü Signal transmission, conversion, allocation function optional

ü Suited to various I/O system

ü Imported PHOENIX covering

ü DIN35 standard installation

Series NO.

Input

Output

Channel

TS100-EX

NAMUR Sensors Mechanical Jionts

Relay Output

1 input & 1 output

TS200-EX

NAMUR Sensors Mechanical Jionts

Relay Output

2 input & 2 output

TS101-EX

NAMUR Sensors Mechanical Jionts

Transistor Output

1 input & 1 output

TS201-EX

NAMUR Sensors Mechanical Jionts

Transistor Output

2 input & 2 output

TS102-EX

NAMUR Sensors

I :0/4-20mA

1 input & 1 output

TS202-EX

NAMUR Sensors

I :0/4-20mA

2 input & 2 output

 Ex-proof Safety Barrier for Industry

Designed according to GB3836.1: 2000 & GB3836.4:2000 requirement, adopt unique patent
technology to realize the isolation between power, signal input and output, largely
improve the Antiinterference capability of the monitor and control circuit, very easy and
safe to use. Connect with all kinds of translators, electric/gas converter, electric/gas
valve localizer, approaching switch, electromagnetic valve, etc and compose intrinsically safe system.

ü  Certification of explosion protection  [Exia]IIC

ü Single/dual channels with very low cost

ü Signal transmission, conversion, allocation function optional

ü Suited to various I/O system

ü Imported PHOENIX covering

ü DIN35 standard installation

Series NO.

Input

Output

Channel

TC100PI-EX

R,S,K,J,T,B,E Thermometry,mV signal

0/4-20mA,
0/1-5V,0/2-10V

1 input & 1 output

TC600PI-EX

R,S,K,J,T,B,E Thermometry,mV signal

0/4-20mA,
0/1-5V,0/2-10V

1 input & 2 output

Series NO.

Input

Output

Channel

TC100PI-EX-SP

R,S,K,J,T,B,E Thermometry,mV signal

0/4-20mA,
0/1-5V,0/2-10V

1 input & 1 output

TC600PI-EX-SP

R,S,K,J,T,B,E Thermometry,mV signal

0/4-20mA,
0/1-5V,0/2-10V

1 input & 2 output

Ex-proof Safety Barrier for Industry

 Designed according to GB3836.1: 2000 & GB3836.4:2000 requirement, adopt unique patent
technology to realize the isolation between power, signal input and output, largely
improve the Antiinterference capability of the monitor and control circuit, very easy and
safe to use. Connect with all kinds of translators, electric/gas converter, electric/gas
valve localizer, approaching switch, electromagnetic valve, etc and compose intrinsically safe system.

Series NO.

Remark

Input

Output

Channel

TA100-EX

DC current input analog detection type safety barrier

0/4-20mA

0/4-20mA,
0/1-5V,0/2-10V

1 input & 1 output

TA200-EX

DC current input analog detection type safety barrier

0/4-20mA

0/4-20mA,
0/1-5V,0/2-10V

2 input & 2 output

TA600-EX

DC current input analog detection type safety barrier

0/4-20mA

0/4-20mA,
0/1-5V,0/2-10V

1 input & 2 output

Series NO.

Remark

Input

Output

Channel

TAF100-EX

DC current input analog operation type safety barrier

0/4-20mA

0/4-20mA,
0/1-5V,0/2-10V

1 input & 1 output

TAF200-EX

DC current input analog operation type safety barrier

0/4-20mA

0/4-20mA,
0/1-5V,0/2-10V

2 input & 2 output

TAF600-EX

DC current input analog operation type safety barrier

0/4-20mA

0/4-20mA,
0/1-5V,0/2-10V

1 input & 2 output

Posted in InventoryList.