SPECIFICATIONS

1. 0.065 % High accuracy.
2. Multi output for integration.
3. Advanced Self diagnostics.

Yokogawa Pressure Transmitter EJA118

 

Model EJA118W, EJA118N and EJA118Y

 

Diaphragm Sealed Differential Pressure Transmitters

 

1. Diaphragm seals are used to prevent process medium form entering directly into the pressure-sensing assembly of the differential pressure transmitter, they are connected to the transmitter using capillaries filled with fill fluid.

2. Model EJA118W, EJA118N and EJA118Y Diaphragm Sealed Differential Pressure Transmitters can be used to measure liquid, gas, or steam flow, as well as liquid level, density, and pressure.

3. They output a 4 to 20 mA DC signal corresponding to the measured pressure differential.

The transmitters also feature remote setup and monitoring through communications with the model BT200/100 BRAIN TERMINAL, CENTUM CS/XL system etc.

 

Features:

 

1. Output Signal “0”:

4 to 20 mA DC, 2-wire system with digital communication

 

2. Failure Alarm:

 

Output status at CPU failure and hardware error;

 

Up-scale:110%, 21.6 mA DC or more(standard) Down-scale: -5%, 3.2 mA DC or less

 

-2.5%, 3.6 mA DC or less (Optional code /F1)

 

Note: Applicable for Output signal code D and E

 

 

3. Supply Voltage “0”:

 

10.5 to 42 V DC for general use and flameproof type

 

10.5 to 32 V DC for lightning protector (Optional code /A)

 

10.5 to 30 V DC for intrinsically safe, Type n, nonincendive, or non-sparking type

 

10.5 to 28 V DC for TIIS intrinsically safe type

 

4. Process Temperature Limits:

 

(See ‘Optional Specifications’ for Explosion-protected types)

 

5. Ambient Humidity Limits:

 

5 to 100 % R.H.(at 40 oC)

 

Model and suffix codes:

ModelSuffix CodesDescription
EJA118WDiaphragm sealed differential pressure transmitter (Flush diaphragm type)
Output SignalD4 to 20 mA DC with digital communication  (BRAIN protocol)
E4 to 20 mA DC with digital communication  (HART protocol) 1
GDigital communication  (PROFIBUS PA protocol) 10
Measurement span   (capsule)M2.5 to 100 kPa {250 to 10000 mmH2O}{10 to 400 inH2O}{25 to 1000 mbar}
H25 to 500 kPa {0.25 to 5 kgf/cm2}{100 to 2000 inH2O}{250 to 5000 mbar}
Wetted parts material 8[Diaphragm]  [Others]
SJIS SUS316L  JIS SUS316L 11
HHastelloy C-276 9  Hastelloy C-276 9
UTitanium  Titanium
Process flange ratingJ1JIS 10K
J2JIS 20K
J4JIS 40K
A2ANSI Class 300             P2 . . . . . . . . . . JPI Class 300
D4DIN PN25/40
D5DIN PN64
Process flange    size / materialD3-inch (80 mm) / JIS S25C
E3-inch (80 mm) / JIS SUS304  12
F3-inch (80 mm) / JIS SUS316 13
Cover flange bolts materialAJIS SCM435
BJIS SUS630
Fill fluid                                                               [Process temp.]   [Ambient temp.]
AFor general use (silicone oil)                    -10 to 250 oC   -10 to 60 oC
BFor general use (silicone oil)                    -30 to 180 oC   -15 to 60 oC
EFor low temperature use (ethylene glycol) -50 to 100 oC   -40 to 60 oC
AAlways A
Capillary length (m)5Specify capillary length from 1 to 10m in . (Example for 2 m : 02)
Installation9Horizontal impulse piping type, left side high pressure
Electrical connection0G1/2 female, one electrical connection
21/2 NPT female, two electrical connections without blind plug Pg 13.5 female
3two electrical connections without blind plug M20 female
9two electrical connections and a blind plug
B1/2 NPT female, two electrical connections and a SUS316 blind plug
Integral indicatorDDigital indicator
EDigital indicator with the range setting switch 7
N(None)
Mounting bracketAJIS SECC
B2-inch pipe mounting (flat type) JIS SUS304
(None)