Yokogawa EJA440A High Pressure Transmitter 4 to 20 mA DC with digital communication HART protocol
The high performance differential pressure transmitter model EJA430A can be used to measure liquid, gas, or steam flow as well as liquid level, density and pressure. It outputs a 4 to 20 mA DC signal corresponding
to the measured differential pressure. Model EJA430A also features remote setup and monitoring through communications with the BRAIN™ terminal and CENTUM CS™ or XL™ or HART® 275 host.
How to choose the Yokogawa EJA440A
EJA440A Gauge Pressure Transmitter | |||
C Capsule | D Capsule | ||
Range | -0.1 to 32 MPa (-15 to 4500 psi) | -0.1 to 50 MPa (-15 to 7200 psi) | |
Span | 5 to 32 MPa (720 to 4500 psi) | 5 to 50 MPa (720 to 7200 psi) | |
Accuracy | ±0.12% | ±0.12% | |
Degrees of protection | IP67, NEMA 4X, and JIS C0920 immersion proof | ||
Certificates | FM, CENELEC ATEX, CSA, IECEx | ||
Output | 4 to 20 mA DC or FOUNDATION™ fieldbus or PROFIBUS PA 2-wire system with digital communication | ||
Supply voltage | BRAIN and HART:10.5 to 42 V DC (10.5 to 30 V DC for Intrinsically safe type) Fieldbus:9 to 32 V DC (9 to 24 V DC for Entity model and 9 to 17.5 V DC for FISCO model) | ||
Ambient temperature | -40 to 85 deg C (-40 to 185 deg F) (general use type) -30 to 80 deg C (-22 to 176 deg F) (with integral indicator) | ||
Process temperature | -40 to 120 deg C (-40 to 248 deg F) (general use type) | ||
Maximum overpressure | 48 MPa (6750 psig) | 60 MPa (8500 psig) | |
Mounting | 2-inch pipe mounting | ||
Wetted parts material | Capsule | SUS316L (Diaphragm material is Hastelloy C-276) | |
Cover flange | SUS316 | ||
Housing | Cast aluminum alloy or SUS316 equivalent stainless steel (optional) |