YOKOGAWA TRANSMITTER EJA110A-EVS4A-92DB/NF1/G72 YOKOGAWA MADE IN JAPAN
YOKOGAW Atransmitter EJA110A-EVS4A-92DB/NF1/G72 Yokogawa made in Japan
YokogawaEJA110A-EMS4A-92DA YokogawaEJA110A-EMH4A-92DA YokogawaEJA110A-EMS4A-22DC YokogawaEJA110A-EMH4A-22DC
YokogawaEJA110A-EMS5A-92DA YokogawaEJA110A-EMH5A-92DA YokogawaEJA110A-EMS5A-22DC YokogawaEJA110A-EMH5A-22DC
YokogawaEJA110A-EMS4A-92NA YokogawaEJA110A-EMH4A-92NA YokogawaEJA110A-EMS4A-22NC YokogawaEJA110A-EMH4A-22NC
YokogawaEJA110A-EMS5A-92NA YokogawaEJA110A-EMH5A-92NA YokogawaEJA110A-EMS5A-22NC YokogawaEJA110A-EMH5A-22NC
YokogawaEJA110A-DHS4A-92DA YokogawaEJA110A-DHH4A-92DA YokogawaEJA110A-DHS4A-22DC YokogawaEJA110A-DHH4A-22DC
YokogawaEJA110A-DHS5A-92DA YokogawaEJA110A-DHH5A-92DA YokogawaEJA110A-DHS5A-22DC YokogawaEJA110A-DHH5A-22DC
YokogawaEJA110A-DHS4A-92NA YokogawaEJA110A-DHH4A-92NA YokogawaEJA110A-DHS4A-22NC YokogawaEJA110A-DHH4A-22NC
YokogawaEJA110A-DHS5A-92NA YokogawaEJA110A-DHH5A-92NA YokogawaEJA110A-DHS5A-22NC YokogawaEJA110A-DHH5A-22NC
YokogawaEJA110A-EHS4A-92DA YokogawaEJA110A-EHH4A-92DA YokogawaEJA110A-EHS4A-22DC YokogawaEJA110A-EHH4A-22DC
YokogawaEJA110A-EHS5A-92DA YokogawaEJA110A-EHH5A-92DA YokogawaEJA110A-EHS5A-22DC YokogawaEJA110A-EHH5A-22DC
Specifications
EJA110A Differential Pressure Transmitter | |||||
L Capsule | M Capsule | H Capsule | V Capsule | ||
Range | -10 to 10 kPa (-40 to 40 inH2O) | -100 to 100 kPa (-400 to 400 inH2O) | -500 to 500 kPa (-2000 to 2000 inH2O) | -0.5 to 14 MPa (-70 to 2000 psi) | |
Span | 0.5 to 10 kPa (2 to 40 inH2O) | 1 to 100 kPa (4 to 400 inH2O) | 5 to 500 kPa (20 to 2000 inH2O) | 0.14 to 14 MPa (20 to 2000 psi) | |
Accuracy | ±0.075% | ±0.065% | ±0.065% | ±0.065% | |
Degrees of protection | IP67, NEMA 4X, and JIS C0920 immersion proof | ||||
Certificates | FM, CENELEC ATEX, CSA, IECEx | ||||
Output | 4 to 20 mA DC, FOUNDATION™ fieldbus or PROFIBUS PA 2-wire system with digital communication | ||||
Supply voltage | BRAIN and HART:10.5 to 42 V DC (10.5 to 30 V DC for Intrinsically safe type) Fieldbus:9 to 32 V DC (9 to 24 V DC for Entity model and 9 to 17.5 V DC for FISCO model) | ||||
Ambient temperature | -40 to 85 deg C (-40 to 185 deg F) (general use type) -30 to 80 deg C (-22 to 176 deg F) (with integral indicator) | ||||
Process temperature | -40 to 120 deg C (-40 to 248 deg F) (general use type) | ||||
Maximum working pressure | 16MPa(2300psi) 3.5MPa(500psi) for L capsule with special materials | ||||
Mounting | 2-inch pipe mounting | ||||
Wetted parts material | Capsule | SUS316L(Diaphragm material is Hastelloy C-276), Hastelloy C-276, Tantalum, Monel | |||
Cover flange | SUS316, Hastelloy C-276, Monel | ||||
Housing | Cast aluminum alloy or SUS316 equivalent stainless steel (optional) |